Optical Desktop Fluorescence Spectrometer

FOB Reference Price:Get Latest Price
$14,999.00 - $17,999.00 / Unit | 1 Unit/Units (Min. Order)
Shipping:
Support Sea freight
Lead Time:
Quantity(Units) 1 - 1 >1
Est. Time(days) 30 Negotiable
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Jilin, China
Brand Name:
CNI
Model Number:
FluSys-405/532
Size:
420x 272x 160 mm
Weight:
840g
Focal Length:
Contat
Wavelength Range:
200-1100nm
Measurement Range:
200-1100nm
Wavelength (nm):
405±5 /532±1 (other wavelengths can be customized)
Power stability (pk-pk, 4 hours):
<1%,3%,5%
Operating temperature (℃):
10-35
Warranty:
1 year
Pixels size:
8 μmx 200 μm
Optical resolution (nm):
<0.5 nm FWHM
Signal-to-noise ratio:
300:1
Integration time:
4ms-10s
Analog channels:
One 12 analog input one 12 analog output
Expected lifetime (hours):
10000
Supply Ability
Supply Ability:
1000 Unit/Units per Month
Packaging & Delivery
Packaging Details
Static free plastic bag, Protective packing
Port
Changchun
Lead Time :
Quantity(Units) 1 - 1 >1
Est. Time(days) 30 To be negotiated
Product Description

Features:

High sensitivity and accuracy

FluSys-405:< 0.5nm

FluSys-532:< 0.5nm

Customized wavelength range and resolution

Fit various applications


Support download for Spectral Analysis 5.0

Applications:

SCrystal fluorescence spectral analysis


Fluorescence spectral analysis of rare earth elements analysis

Water quality analysis

Turbidity control

Gasoline analysis

DNA analysis

Characteristic:

Dimensions: 420x 272x 160 mm

405/ 532 excitation laser source with adjustable and stable power

Simple, fast measurement and easy operation

flexible and stable sampling, various forms in analyzng samples

external power supply (charging), with vehicle-mounted charger

dustproof, waterproof, anti-vibration, Anti-glare interference in wild environment usage

Basic components:

FPB-405/ 532 Fluorescence probe


405/ 532 Fiber laser


Fiber spectrometer: Aurora4000


PC data processing unit

Man-machine Interface

Specifications

Laser

Wavelength (nm)
405±5 (other wavelengths can be customized)
532±1 (other wavelengths can be customized)
Mode
Near TEM00
TEM00
Power stability (pk-pk, 4 hours)
<1%,3%,5%
<1%,3%,5%
Operating mode
CW
CW
Warm-up time (minutes)
<5
<10
Operating temperature (℃)
10000
10000
Warranty
1 year
1 year
Expected lifetime (hours)
10000
10000

Spectrometer


Wavelength range
405-850 nm(spectrometer wavelength range and resolution can be customized)
532-1100 nm(spectrometer wavelength range and resolution can be customized)
Optical resolution (nm)
<0.5 nm FWHM
Pixels(pixels)
3648
Pixels size
8 μmx 200 μm
Dimensions (mm)
149x 105x 46
Weight (g)
840
Signal-to-noise ratio
300:1
Integration time
4ms-10s
Power consumption
450 mA@ 5V DC

Data transfer speed
Full scans into memory every 4 milliseconds with USB 2.0
Full scans into memory every 18 milliseconds with USB 1.1
Inputs/outputs
5 inputs and 5 outputs (opto-isolator inputs/outputs)
Analog channels
One 12 analog input one 12 analog output
Connector
30pin

Fluorescence Probe

Excitation wavelength (nm)
405 (Spectrum linewidth ~1 nm)
532 (Spectrum linewidth ~1 nm)
Probe focus length (mm)
7.5
Main material of probe
Black anodised aluminium, 111*38*14.8mm head 38mm long

Fiber configuration
Two single fiber (100 um excitation fiber, 200 um receiving optical fiber) N.A.=0.22, SMA905 connector, PVC/metal sheath; 1 m length

Filter effect
Can be completely filtered out of the stray light received, and eliminate the quartz fiber generated background scattering

(O.D.> 5 @ laser wavelength)
Working temperature (℃)
0-40
Connection port
SMA 905 connector

Software

Optical spectrum analysis
Spectrum Analysis Software
Operating system
Windows XP/ Win7 (32 bits or 64 bits)
Accessories

Optical Filter

CNI offers band-pass filter, high-pass filter, low-pass filter, dichroic filter, beam splitter, etc.

Laser Power Meter

Two types: thermoelectric and photoelectric. The photoelectric type can be divided into high precision, desktop and handheld. Thermopile type is with wide measuring range.

Laser Goggles

Beautiful shape, comfortable fit, high definition, extrusion deformation prevention material, able to protect human eyes from the laser radiation damage from 200nm to 1100nm.Bottle Moulding Machine.

Spectrum Calibration Laser

The spectrum of it comply with NST international standard, and it is used for spectrum instruments wavelength calibration and spectrum calibration

HLS-1000 Halogen Tungsten

Wide range of continuous spectrum (340-2000nm), can be used for sample detection of absorbance and transmittance...

Laser Safety Protection Board

An sufficient safety laser protection board adopts sandblasting surface treatment, has no selectivity to light source and is able to protect against laser and strong light effectively.

Packing & Delivery
Certifications
Company Information

    Changchun New Industries (CNI) founded in 1996, located in Changchun, CHINA, is a leading manufacturer of solid-state and diode laser systems. Our products include green laser, blue laser, yellow laser, red laser, RGB laser, infrared laser, UV laser, single longitudinal mode laser and Q-switched laser systems. CNI lasers are featured with high performance, low cost and excellent laser beam quality, which are specifically designed for OEM, scientific, industrial and instrumentation use. In addition, CNI lasers are ISO-9001, FDA, CE and JQA certified.


    CNI also provides laser components and accessories, we aim to offer customers complete laser solutions for all solid state lasers, diode lasers, laser marking system with our most convenient and rapid service.

Exhibitions
Contact Us